E-mail Us
dc digital meter
dc digital meter
dc inline watt meter
dc energy meters
dc energy meter price

PZ72L-DE DC Power Analyzer

  • Measurement: 1-circuit DC kWh, kVarh, U, I, P and etc

  • Accuracy: 0.5%

  • Rated Voltage: 1000V DC

  • Rated Current: 10A DC (direct connect); 0/4~20mA DC (via Hall Sensor); 75mV (via Shunts)

  • Power Supply: 85~265V AC/DC; 20~60V DC

  • Communication: RS485 (MODBUS-RTU)

  • ±12V Power Ouput: Paired with Hall Sensor

  • DI/DO Function: 2/4-channel DI&2-channel DO

  • Multi-rate/tariff: 4 Tariff Rates etc

  • Standard&Certificate: CE Certificates

Features of PZ72L-DE DC Power Analyzer

dc current meter

Specifications of PZ72L-DE DC Power Analyzer

1. Function Overview

FunctionDescription&Value
Measurement

1-circuits DC Voltage, Current, Power, kWh

Display

LCD display

Communication(Optional)

RS485, Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)

Baud Rate 1200~38400 bps etc.

DI/DO Switching(Optional)

DI (Digital input): 2-channel digital input, dry contact, built-in power supply

DO (Digital output): 2-channel digital output (relay output) with NO Contact, Capacity: 2A/30V DC or 2A/250V AC

±12V Power Output(Optional)

Serve as the power supply for 1 Hall Sensors with ±12V DC

Multi-rate/tariff(Optional)

2 Time Schedules; 4 Time Zone for a year; 12 time periods by days set for 1 time schedule; 4 Tariff Rates (Spike, Peak, Flat, Valley); Min. Time Interval=15 min.


2. Main Parameters

ParameterDescription&Value
InputRated VoltageDC Voltage Input: 0~1000V DC (via direct connetion);  Input Resistance: ≥ 6kΩ/V
Rated CurrentDC Current Input: 10A DC (via direct Connection); 0~20mA or 4~20mA (via Hall Sensors); 75mV (via Shunts)
Overload

Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second

Power Consumption

Power consumption of each current input circuit is less than 1mW

Measuring AccuracyClass0.5%
Power SupplyVoltage Range85-265V AC/DC; 20~60V DC (±20%)
Power Consumption

≤ 2W

Pulse Constant


Voltage and current specifications:750V、300A,Default pulse constant:100imp/kWh


Voltage and current specifications:1000V、300A,Default pulse constant:100imp/kWh

Insulation resistance

≥ 100MΩ

Power frequency withstand voltage

Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min;

Between Power supply、switching output、Current Input、voltage Input AC 2 kV 1min;

Between Transmitting、Communication、Pulse Output、switching input AC 1kV 1 min;


3. Environment

ConditionDescription&Value
Temperature

Operation: -25℃~+65℃; Storage: -40°C ~+80°C

Humidity

≤95%RH, no condensation, without corrosive gas

Altitude

≤ 2500m


Drawings of PZ72L-DE DC Power Analyzer

Thank you for your attention to Acrel
Let's know your need of smart energy meter.