Support Data Download Resume&Data Storage
Collect Data from up to 64 Devices
Diverse Communication Methods
Multiple Communication Protocol
Local&Remote Configuration Setting
Stable Operation
LVD; EMC (level 4)
Support Data Download Resume&Storage ● Data transmitted by XML&JSON Format ● AES Data Encryption ● Equipped with standard 8GB SD card (Max. 32GB) ● Local Data Storage for up to a month |
Collect Data from up to 64 Devices ● Downstream Protocol: MODBUS-RTU, MODBUS-TCP and etc. ● All type of Energy Data: Electricity, Gas, Water, Oil, Cold, Heat and etc. ● Up to 8 Serial Interface for Data Collection |
Diverse Communication Methods ● Upstream: 4G, 3G, 2G, WiFi, Ethernet ● Downstream: RS485, LoRa ● Support VPN Network |
Multiple Communication Protocol ● MODBUS ● MQTT ● BACnet-IP ● OPC UA ● WEBService ● SNMP ● .......etc |
Local&Remote Configuration Setting ● Alarm setting for Downstream Devices ● Batch devices setting&adjustment ● Cut off extra Waste on Adjustment |
Stable Operation ● Double wide Voltage (DC / AC 85V ~ 265V) ● Reverse Connection Protection ● Built-in Linux OS ● EMC Level 4 ● Opto-coupler Isolation |
Hardware | ||
Technical Data | Index | |
Power | Voltage | AC 85 V ~265 V |
Consumption | ≤10W | |
Processing element | ARM32 digit Free scale ARM9 i.MX2xx 454MHz | |
Inner board memory | 64MB DDR2 internal memory + 128MB NAND Flash + 8G SD Card Electronic hard disk | |
Serial interface | Two channels coupling isolation RS485 | |
Ethernet interface | 1 channel 10/100 self-adaption capacity | |
SD card interface | Supports SD/MMC memory cards of not less than 512 M, supports hot-plug and plug-and-play breakpoints to continue data storage | |
Safety | Power frequency withstand voltage: AC 2kV 1min between communication terminal and auxiliary power supply | |
Insulation resistance: input, output to shape>100MΩ | ||
Environment | Working Temperature:-20℃~+55℃ Storage Transport Temperature:-25℃~+70℃ Relative Humidity :≤95%(+25℃) Altitude:≤2500m | |
EMC Testing | IEC61000-4-2 ESD immunity test Class 4 IEC61000-4-4 Resistance test of electric fast transient pulse group Class 4 IEC61000-4-5 Surge (shock) immunity test Class 4 IEC61000-4-6 Conductive disturbance immunity of RF field induction Class 3 |
Software | |
Configuration | C/S architecture ANetCM configuration management software, open template management, plain text or excel engineering information management |
Fast update | ANetOS provides 1-3 seconds extreme speed configuration update 3-7 seconds firmware upgrade update. If the error configuration is updated, the loss-proof algorithm automatically returns the device to the pre-update configuration state within 3-5 seconds. If the upgrade has a problem firmware, the damage prevention algorithm automatically returns the device to the pre-upgrade state within 5-10 seconds. |
Network communication mode | Socket mode, support XML format compression upload, provide AES encryption and MD5 identity authentication and other security requirements |