AMC96L-AI3 Three Phase Ammeter Analyzer

  • AC current: AC 1A, 5A

  • Four keys to communication and set parameters

  • LCD display for three phase current measurement

Features of AMC96L-AI3 Three Phase Ammeter Analyzer

Accuracy

Active energy: Class 0.5

Frequency

Range: 45-65Hz

Auxiliary power supply

AC/DC 85~265V

Pulse output

1600-160000imp/kWh

Consumption
Voltage: Power consumption <0.5VA;
Current: Power consumption< 0.5VA;
Auxiliary power supply:power consumption≤10VA


ac power monitoring device

Installation

Panel mounted

Dimension(L*W*H)

Panel size (L×W): 96*96mm

Cutout (L×W): 92*92mm

Housing (L×W×H): 90*90*77.8mm

Relay

DC 30V/3A AC 220V/3A

Consumption

0.2%

ac power monitor


Specifications of AMC96L-AI3 Three Phase Ammeter Analyzer

Technical ParametersValue
InputConnectionSingle phase-2 wire,3 phase-3 wire,3 phase 4-wire
Frequency45-65Hz
VoltageRating:
Single-phase:AC 100V, 400V
Three-phase:AC 3x57.7V/100V(100V), 3x220V/380V(400V)
3x380V/660V(660V)(96 size only)
Note:72 profile not suitable for high voltage application
Overload:1.2 fold rating(continuous):2 fold rating for 1 second
Power consumption:<0.5VA
CurrentRating:AC 1A, 5A
Overload:1.2 fold rating(continuous):10 fold rating for 1 second
Power consumption:<0.5VA
OutputElectric energyOutput mode:open-collector photo-coupler pulse
Pulse constant:10000imp/kWh(settable),see wiring diagram for details
CommunicationRS485 port,Modbus-RTU protocol,DLT645 protocol(versions 09 and 97),baud rate 1200-38400
FunctionSwitching inputDry contact input, built-in power supply
Switching outputOutput mode: Relay normally open contact output
Contact capacity:AC 250V/3A、DC 30V/3A
Analog output1-5V,4-20mA
Accuracy ClassFrequency:0.05Hz,Current、Voltage;0.2 class,Reactive
Power:1.0 class, Reactice Electric energy:1.0 class active
Power:0.5 class,active electric energy:0.5 class,2-31th harmonic
measurement:±1%
Power SupplyAC/DC 85-265V Power consumption≤10VA
SecurityPower frequency
withstand voltage
Between Power supply//Switching Output//Current input//voltage input and
Transmitting//Communication//Pulse Output//switching input AC 2kV 1min;
Between Power supply, switching output, Current input, voltage input AC 2kV 1min;
Between Transmitting, Communication, Pulse Output, switching input AC 1kV 1 min;
Insulation resistanceInput, Output end to machine enclosure>100MΩ
EnvironmentTemperaturework:-25℃~+65℃ storage:-40℃~+80℃
Humidity≤93%RH Non-condensing
Altitude≤2500m


Drawings of AMC96L-AI3 Three Phase Ammeter Analyzer

Thank you for your attention to Acrel
Let's know your need of smart energy meter.