Measurement: DC Current of up to 24 Circuits (with Hall Sensors); Voltage of Busbar
Communication: RS485 (MODBUS-RTU)
Application: Paired with PV Combiner Box for DC Multi-circuits Monitoring
Temperature Monitoring: Inner Temperature of PV Combiner Box
DI Function: 3-channel Digital Input
Display: LCD Display
Installation: 35mm DIN Rail (Main Body); Perforation (Cable)
Power Supply: 1000V DC or 1500V DC
Standard&Certificate: CE; LVD; EMC
Multi-circuits Measurement up to 24 DC Circuits ● Input Channel: up to 24 Circuits ● LED Indicator for Re-flux, Disconnection, Over-current ● Rated Current: 20A ● Accuracy: 0.5 Class ● Voltage Measuring Range: up to 1500V (Busbar) |
3-Channel DI Switch Status Monitoring ● DI Status of Lightning Protector and DC CB ● Octocoupler or dry Contact |
Temperature Measuring & Over-temperature Alarm Function ● Measuring the inner Temperature of DC PV Junction Box ● Thermistor: NTC ● Range of Measuring: -20℃~+100℃ |
Keypads HMI for Programming ● Communication(address, baud rate and etc.) ● Over-temp Alarm Threshold |
LCD Display ● English Interface ● Data Display |
Easy Installation ● Perforated Hole for Cable to pass through ● DIN Rail Installation ● Module Connected by Data Line |
Item | AGF-M4T | AGF-M8T | AGF-M12T | AGF-M16T | AGF-M20T | AGF-M24T |
Input channels | 4 | 8 | 12 | 16 | 20 | 24 |
Rated current | DC 0~20A | |||||
Response time | 1s | |||||
Accuracy | 0.5 class | |||||
Temperature coefficient | 400ppm | |||||
RS485 communication | RS485/ModBus-RTU protocol,4800/9600/19200/38400bps | |||||
Additional function | ||||||
Switch input | 3-way input(optocoupler or dry contact mode) | |||||
General technical parameters | ||||||
Temperature/ Humidity | Working temperature: -35~+65℃, humidity95%,no condensation, no corrosion gas place *Display module work temperature:-20~+70℃ | |||||
Temperature measurement function | To measure the inner temperature of box (-20℃~100℃) | |||||
Altitude | ≤3000m | |||||
Insulation resistance | ≥100MΩ | |||||
Industrial frequency withstand voltage | power/communication/switching input/cell voltage input--AC 2kV/1min (When the auxiliary power supply is DC1500V, the withstand voltage between the power supply, photocell input and other circuit is AC 2.7kV) Current input/power、cell voltage 、communication、switching state—AC3.5kV/1min | |||||
EMC | GB_T 17626.2-2006; Electrostatic discharge immunity test 3rd grade, air discharge 8kV, contact discharge 6kV. | |||||
GB_T 17626.4-2008; Electrical fast transient immunity test grade 4, common mode 4kV, difference mode 2kV | ||||||
GB_T 17626.5-2008; Surge(shock) immunity test grade 4, common mode 4kV, difference mode 2kV | ||||||
GB_T 17626.8-2006; Power frequency magnetic field immunity test grade 4 |