Acrel DJSF1352-RN UL DC Power Energy Meter

DJSF1352-RN DC Dual-circuits Monitoring DIN Rail Energy Meter

● Measurement: kWh, kVarh, Power, Current, Voltage and etc

● Current Rating: -/75mV (with Shunt); -/4~20mA (with Hall Sensor)

● Voltage Rating: 0~1000V DC

● Application: DC Battery; Charging Pile; Solar PV and etc

● Communication: RS485 (MODBUS-RTU)

● Extra Function: Dual DC Circuits Monitoring; Secondary RS485 (MODBUS-RTU); Built-in Bipolar Power Source (for Hall Sensors); DO/DI Function

● Display: LCD Display

● Dimension: 72*71*87.8mm (L*W*H)

● Installation: 35mm DIN Rail

● Power Supply: 85~265V AC/DC; 24V(±10%) DC; 48V(±10%) DC

● Standard&Certificate: CE

● 0~1000V DC

● Dual DC Circuits Monitoring

● DO/DI Function

Features of Acrel DJSF1352-RN UL DC Power Energy Meter

Acrel Smart Meter Introduction

Ul Energy Meter

DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base stations, DC charging piles, solar photovoltaic, and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system. For the actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, and computers to form a measurement and control system. The meter can have an infrared communication interface and RS-485 communication interface and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.

Djsf1352 Ul Energy MeterUl Power Meter

The meter can have a relay alarm output and digital input function; You can set the ratio, alarm, and communication through the meter panel keys according to different requirements. The meter can have event recording of the switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), and maximum and minimum value recording functions of voltage and current power.

Acrel Smart Meter Wiring Chart

Djsf1352 Ul Energy Meter Factory

Wiring with Shunt

Djsf1352 Ul Energy Meter Manufacturer

Wiring with Hall Sensor

Djsf1352 Ul Meter

Acrel Smart Meter Solution Structure

Djsf1352 Ul Power Meter

Acrel Smart Meter ApplicationsDjsf1352 Ul Smart Energy Meter Applications

Specifications of Acrel DJSF1352-RN UL DC Power Energy Meter

1. Technical Parameter

Technical parameters

Indicators

Input

Nominal value

Voltage input range

Current input

DC 0-1000V

See the physical wiring diagram

Shunt:0-75mV;

Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on.

Overload

1.2 times rated (continuous); 2 times rated/1 second;

Power consumption

Voltage: ≤0.2VA, current ≤0.1VA

Accuracy class

Class 1

Function

Display

8-bit segment LCD screen (LCD)

Communication Interface

RS485, infrared

Communication protocol

Modbus-RTU,DL/T 645-2007

Switch

Switch output

2 Relay outputs, 2A/30VDC or 2A/250VA

Switch input

2 dry contact inputs

Pulse output

A second pulse output, a energy pulse output

See the SYS->PLUS display in the meter menu setting

For example: The meter displays 100, which is 100imp/kWH

Power Supply

Voltage range

AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)

Power consumption

≤ 3W

Power frequency withstand voltage

Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1minPower supply // Relay output // Voltage input // Current input 3kV/1minPulse output // Communication interface // Switch input 2kV/1min

Insulation resistance

≥ 40M Ω

Average barrier-free working hours

≥50000h

Environment

Temperature

Normal operating temperature: -25 °C ~ +65 °C;

Limit working temperature: -40 °C ~ +70 °C;

Storage temperature: -40℃~+80℃

Humidity

≤93%RH, no condensation, no corrosive gas

Altitude

≤2500m


2. Pulse Constant

Maximum power

999.9W

10000

imp/kWh

9.999kW

1000

imp/kWh

99.99kW

100

imp/kWh

999.9kW

10

imp/kWh

9999kW

1

imp/kWh


Details of Acrel DJSF1352-RN UL DC Power Energy Meter

Acrel Smart Meter Details

Dual Independent DC Circuits Monitoring
● For Twin EV Charger&Battery
● Voltage Input:DC 0~1000V
● Current Input (by Shunt): 0~75mV
● Current Input (by Hall Sensor): 0~5V, 0~10V, 0~20mA, 4~20mA
Djsf1352 Ul Power Meter Details.
Built-in Bipolar Power Source
● Power Supply for Hall Effect CT
● Range: DC -12V ~ DC +12V
Djsf1352 Ul Power Meter Factory China
Optional Dual RS485 Communication
● Protocol: MODBUS-RTU
● 1 RS485 (standard)
Djsf1352 Ul Energy Meter Company
DO/DI Function
● 2 DO (2A/30V DC; 2A/250V AC)
● 2 DI (dry contact)
Djsf1352 Ul Energy Meter For Sale
LCD Display
● Parameter Display
● Programming Interface
Djsf1352 Ul Energy Meter Wholesale
Keypads HMI for Programming
● Parameter Display Setting
● Communication
Djsf1352_Ul_Energy_Meter_Keypads

PIN Overview of DJSF1352-RN

Djsf1352 Ul Energy Meter Features

Acrel Smart Meter InstallationsDjsf1352 Ul Energy Meter Dimensions

Djsf1352 Ul Energy Meter Installation Instruction

Thank you for your attention to Acrel
Let's know your need of smart energy meter.
Acrel will get in touch with you ASAP.
*
*
*